v50 Steam/Premium information for editors
  • v50 information can now be added to pages in the main namespace. v0.47 information can still be found in the DF2014 namespace. See here for more details on the new versioning policy.
  • Use this page to report any issues related to the migration.
This notice may be cached—the current version can be found here.

Editing User talk:Hussell

Jump to navigation Jump to search

Warning: You are not logged in.
Your IP address will be recorded in this page's edit history.


The edit can be undone. Please check the comparison below to verify that this is what you want to do, and then save the changes below to finish undoing the edit.

Latest revision Your text
Line 9: Line 9:
 
:I'm aware that it's awkward to get the things running the first time. It's a disadvantage of using doors for everything. Unfortunately, it seems to be an unavoidable disadvantage. In the Data Latch, if the changes you suggest are made, then the output signals will both go to CLOSED while the clock signal is off if the data signal turns on and off. Even if the plate trigger threshold is lowered, turning the data signal on and off would eventually annihilate enough water to send both outputs to the CLOSED state. [[User:Hussell|Hussell]] 00:52, 10 November 2009 (UTC)
 
:I'm aware that it's awkward to get the things running the first time. It's a disadvantage of using doors for everything. Unfortunately, it seems to be an unavoidable disadvantage. In the Data Latch, if the changes you suggest are made, then the output signals will both go to CLOSED while the clock signal is off if the data signal turns on and off. Even if the plate trigger threshold is lowered, turning the data signal on and off would eventually annihilate enough water to send both outputs to the CLOSED state. [[User:Hussell|Hussell]] 00:52, 10 November 2009 (UTC)
  
----
+
::Bro, you should try some gear toggles.  They are instant, I think, and toggle.  Also, the pumps may actually only check for power every so ofton. Maybe this is the delay.--[[User:Zchris13|Zchris13]] 17:15, 13 November 2009 (UTC)
Bro, you should try some gear toggles.  They are instant, I think, and toggle.  Also, the pumps may actually only check for power every so ofton. Maybe this is the delay.--[[User:Zchris13|Zchris13]] 17:15, 13 November 2009 (UTC)
 
 
Good luck.
 
Good luck.
  

Please note that all contributions to Dwarf Fortress Wiki are considered to be released under the GFDL & MIT (see Dwarf Fortress Wiki:Copyrights for details). If you do not want your writing to be edited mercilessly and redistributed at will, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource. Do not submit copyrighted work without permission!

Please sign comments with ~~~~

To protect the wiki against automated edit spam, we kindly ask you to solve the following CAPTCHA:

Cancel Editing help (opens in new window)