Just used cave-in method to pierce a single deep aquifer. I assume that constructed layers still don't work, but haven't tested them (otherwise I would have specifically mentioned not to try using constructed walls.)

A weird glitch: the fallen rock morphs to the rock type of the layer it lands to.

I can confirm this. --Tarran 01:34, 26 April 2010 (UTC)

Of the methods on the old page: looks like the speed and pump methods are still possible, though I was not able to pull them off. I was getting path finding issues where a dwarf thought it was stuck even though there was a clear path, and so was more fun than necessary. --Droid 04:27, 5 April 2010 (UTC)

Draining Method

I just embarked on a site where a surface river drops several z-levels into a canyon, ending up one z-level below an aquifer level. I decided to try punching through the aquifer by draining a large area into the lake and walling off a stairwell in the drained area. Unfortunately, due to the new channelling designation, I now have six soggy dwarf corpses in the canyon, and a melancholy dwarf trading baleful glares with a couple local harpies. The miners basically just dig a down ramp and then jump down into the flow, they seem to even do this if you play with their digging sides so that they have no reason to path through the channelled square.

I might have had more success if I had dug out a larger area unconnected to the river at first, and then breached the canyon wall with a single dwarven sacrifice, but it really seems as though there's no safe way to alter flows with the new channelling system.

Apologies in advance if I didn't set up this talk discussion edit correctly, I don't really understand witiquette. --Njero 05:58, 9 April 2010 (UTC)

Cave-in method needs tutorial

I tried penetrating an aquifier layer using the cave-in method and wound up with a room of 7/7 water filled with chunks of stone. Flow of water into the aquifier layer did not stop, and I was unable to penetrate it. Could someone please through together a diagram showing how to use the cave-in method? The wiki article is not very specific.--208.81.12.34 15:15, 21 April 2010 (UTC)