v50 Steam/Premium information for editors
- v50 information can now be added to pages in the main namespace. v0.47 information can still be found in the DF2014 namespace. See here for more details on the new versioning policy.
- Use this page to report any issues related to the migration.
This notice may be cached—the current version can be found here.
Difference between revisions of "40d:Machinery/Examples"
Jump to navigation
Jump to search
m |
(Fixing links within namespace (524/997)) |
||
Line 1: | Line 1: | ||
{{av}} | {{av}} | ||
− | == Draining a | + | == Draining a {{L|pond}} == |
1. A Pond To Drain <br/> | 1. A Pond To Drain <br/> | ||
<pre>≈........ | <pre>≈........ | ||
Line 8: | Line 8: | ||
≈........</pre> | ≈........</pre> | ||
− | 2. Add Some | + | 2. Add Some {{L|wall}}s to control output, and an access ramp (leaving access is a good idea)<br/> |
<pre>≈.....▲.. | <pre>≈.....▲.. | ||
Line 16: | Line 16: | ||
≈........</pre> | ≈........</pre> | ||
− | 3. add 3 | + | 3. add 3 {{L|Floor|floor tiles}} above the gap, then build your windmill<br/> |
<pre>......▼.. | <pre>......▼.. | ||
Line 24: | Line 24: | ||
.........</pre> | .........</pre> | ||
− | 4. build a | + | 4. build a {{L|lever}} and {{L|gear assembly}}, then link your lever to the gear<br/> |
<pre>≈...ò.▲.. | <pre>≈...ò.▲.. | ||
≈≈≈.o════ | ≈≈≈.o════ | ||
Line 31: | Line 31: | ||
≈........</pre> | ≈........</pre> | ||
− | 5. Finally, throw the lever, add your | + | 5. Finally, throw the lever, add your {{L|screw pump}} and the final wall section<br/> |
<pre>≈...ó.▲.. | <pre>≈...ó.▲.. | ||
≈≈≈o═════ | ≈≈≈o═════ | ||
Line 47: | Line 47: | ||
≈..╚═╝...</pre> | ≈..╚═╝...</pre> | ||
− | This allows | + | This allows {{L|water}} to flow past the pump when the pump is off, meaning that one pipe with a pump at each end can send water either direction, based on which pump is on. It also allows for maintenance access from the pipe, at the cost of 3 extra wall sections and one extra floor. |
== A simple pump with lever == | == A simple pump with lever == | ||
Line 59: | Line 59: | ||
########## | ########## | ||
− | The right gear does not need to lie on the screw pump, as long as it's | + | The right gear does not need to lie on the screw pump, as long as it's {{L|orthogonal}} to the gear that -is- placed over the pump. |
[[Category:Constructions]] | [[Category:Constructions]] |
Revision as of 16:45, 12 April 2010
This article is about an older version of DF. |
Draining a Template:L
1. A Pond To Drain
≈........ ≈≈≈...... ≈≈≈...... ≈≈≈...... ≈........
2. Add Some Template:Ls to control output, and an access ramp (leaving access is a good idea)
≈.....▲.. ≈≈≈.o════ ≈≈≈...... ≈≈≈o═════ ≈........
3. add 3 Template:L above the gap, then build your windmill
......▼.. ....+++++ ....+++.. ...++++++ .........
4. build a Template:L and Template:L, then link your lever to the gear
≈...ò.▲.. ≈≈≈.o════ ≈≈≈..*... ≈≈≈o═════ ≈........
5. Finally, throw the lever, add your Template:L and the final wall section
≈...ó.▲.. ≈≈≈o═════ ≈≈≈%%*... ≈≈≈o═════ ≈........
Alternatives
- Skip the lever and gear and power the pump directly, "always on".
- The "Blowback" wall method:
≈...ó.▲.. ≈≈≈o═════ ≈≈≈%%*... ≈≈≈o.╔═══ ≈..╚═╝...
This allows Template:L to flow past the pump when the pump is off, meaning that one pipe with a pump at each end can send water either direction, based on which pump is on. It also allows for maintenance access from the pipe, at the cost of 3 extra wall sections and one extra floor.
A simple pump with lever
Side view:
=O= <- windmill supported by unlinked gear assembly ** <- two gear assemblies: left gear is linked to lever @@ <- screw pump ~=~=~##### <- water ##########
The right gear does not need to lie on the screw pump, as long as it's Template:L to the gear that -is- placed over the pump.