v50 Steam/Premium information for editors
  • v50 information can now be added to pages in the main namespace. v0.47 information can still be found in the DF2014 namespace. See here for more details on the new versioning policy.
  • Use this page to report any issues related to the migration.
This notice may be cached—the current version can be found here.

Editing Screw pump

Jump to navigation Jump to search

Warning: You are not logged in.
Your IP address will be recorded in this page's edit history.

If you are creating a redirect to the current version's page, do not use any namespace. For example: use #REDIRECT [[Cat]], not #REDIRECT [[Main:Cat]] or #REDIRECT [[cv:Cat]]. See DF:Versions for more information.

The edit can be undone. Please check the comparison below to verify that this is what you want to do, and then save the changes below to finish undoing the edit.

Latest revision Your text
Line 108: Line 108:
 
* The order in which the screw pumps were constructed matters. If built from lowest to highest, they will be able to transfer liquids one z-level per tick. However, if built from highest to lowest, they will transport liquids all the way from the bottom to the top in just one tick.
 
* The order in which the screw pumps were constructed matters. If built from lowest to highest, they will be able to transfer liquids one z-level per tick. However, if built from highest to lowest, they will transport liquids all the way from the bottom to the top in just one tick.
  
===Improved magma pump stack===
+
===Improved Magma Pump Stack===
  
 
Because a pump stack pumping magma is known to cause significant [[Maximizing_framerate|lag]], a [http://www.bay12forums.com/smf/index.php?topic=72296.0 new type of pump stack] was developed by [http://www.bay12forums.com/smf/index.php?action=profile;u=19835 NecroRebel] that causes a much smaller drop in [[FPS]].  Changing the single tile magma chamber at the output of every pump from a 1 x 1 to a 3 x 3 area reduces the lag to 1/15th of that caused by the original pump stack. The designer hypothesizes that the larger chamber requires many fewer temperature calculations when magma is pumped in or out; that also implies that there will be no FPS improvement for water pumps by using this design.
 
Because a pump stack pumping magma is known to cause significant [[Maximizing_framerate|lag]], a [http://www.bay12forums.com/smf/index.php?topic=72296.0 new type of pump stack] was developed by [http://www.bay12forums.com/smf/index.php?action=profile;u=19835 NecroRebel] that causes a much smaller drop in [[FPS]].  Changing the single tile magma chamber at the output of every pump from a 1 x 1 to a 3 x 3 area reduces the lag to 1/15th of that caused by the original pump stack. The designer hypothesizes that the larger chamber requires many fewer temperature calculations when magma is pumped in or out; that also implies that there will be no FPS improvement for water pumps by using this design.
  
====Newer magma pump breakthroughs====
+
====Newer Magma Pump Breakthroughs====
  
 
Newer breakthroughs in magma pump design have since made the 3x3 reservoir design obsolete.
 
Newer breakthroughs in magma pump design have since made the 3x3 reservoir design obsolete.

Please note that all contributions to Dwarf Fortress Wiki are considered to be released under the GFDL & MIT (see Dwarf Fortress Wiki:Copyrights for details). If you do not want your writing to be edited mercilessly and redistributed at will, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource. Do not submit copyrighted work without permission!

To protect the wiki against automated edit spam, we kindly ask you to solve the following CAPTCHA:

Cancel Editing help (opens in new window)

Templates used on this page:

This page is a member of 2 hidden categories: