- v50 information can now be added to pages in the main namespace. v0.47 information can still be found in the DF2014 namespace. See here for more details on the new versioning policy.
- Use this page to report any issues related to the migration.
Difference between revisions of "Fire-safe"
LethosorBot (talk | contribs) m (LethosorBot moved page DF2014:Fire-safe to Fire-safe: Migrating v50 page (1229/4618) (content)) |
m |
||
(4 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
− | {{Quality|Superior | + | {{Quality|Superior}} |
{{av}} | {{av}} | ||
{{Material properties}} | {{Material properties}} | ||
− | '''Fire-safe materials''' are those that are not damaged by [[fire]]. These materials include [[glass]], most [[metal]] (bismuth, lead, tin, zinc, and all three pewters | + | '''Fire-safe materials''' are those that are not damaged by [[fire]]. These materials include [[glass]], most [[metal]] (everything ''but'' [[bismuth]], [[lead]], [[tin]], [[zinc]], and all three pewters) and most [[stone]]. [[Nether-cap]] is the only [[wood]] that can withstand fire (and even [[magma]]) thanks to its fixed temperature, but the game does not recognize it as a fire-safe building material. Counterintuitively, [[Bituminous coal]], [[lignite]], [[charcoal]], and [[coke]] '''are''' considered fire-safe, since they only catch fire when they're hot enough (see below). |
− | Fire-safe materials are only required when the object is going to come into contact with extreme heat, such as all conventional [[furnace]]s and the [[metalsmith's forge|forge]]. For the magma-powered versions of these buildings, as well as anything that will be in direct contact with magma (such as [[floodgate]]s), fire-safe | + | For the purpose of job item requirements (e.g. in custom [[reaction]]s or when constructing certain buildings), only [[bar]]s, [[block]]s, [[stone]], [[log]]s, and [[anvil]]s can be classified as "fire-safe materials" - all other item types are rejected outright. Fire-safe materials are only required when the object is going to come into contact with extreme heat, such as all conventional [[furnace]]s and the [[metalsmith's forge|forge]]. For the magma-powered versions of these buildings, as well as anything that will be in direct contact with magma (such as [[floodgate]]s), fire-safe is not enough: it has to be [[magma-safe]]. |
− | As far as the game is concerned, only materials which are stable at the [[temperature]] {{ct|11000}} (i.e. MELTING_POINT/BOILING_POINT/IGNITE_POINT/HEATDAM_POINT greater than 11000 and COLDDAM_POINT less than 11000) are considered fire-safe. Despite this temperature being considered fire-safe, actual [[fire]] can generate temperatures significantly higher | + | As far as the game is concerned, only materials which are stable at the [[temperature]] {{ct|11000}} (i.e. MELTING_POINT/BOILING_POINT/IGNITE_POINT/HEATDAM_POINT greater than 11000 and COLDDAM_POINT less than 11000) are considered fire-safe. Despite this temperature being considered fire-safe, actual [[fire]] can generate temperatures significantly higher - in particular, all burning items generate temperatures up to 200 degrees ''above'' their material's ignite point, so once a "fire-safe" item manages to get ignited (e.g. by exposure to [[magma]]), it can easily spread further. For practical purposes, anything which has an IGNITE_POINT should be treated as not fire-safe. |
{{Category|Materials}} | {{Category|Materials}} | ||
{{Category|Physics}} | {{Category|Physics}} |
Latest revision as of 11:53, 22 June 2024
v50.14 · v0.47.05 This article is about the current version of DF.Note that some content may still need to be updated. |
Material properties |
Defined: Value • Color • Density • Strain at yield • Temperature values |
Derived: Magma safety • Fire safety |
Fluids: Depth • Flow • Pressure |
Fire-safe materials are those that are not damaged by fire. These materials include glass, most metal (everything but bismuth, lead, tin, zinc, and all three pewters) and most stone. Nether-cap is the only wood that can withstand fire (and even magma) thanks to its fixed temperature, but the game does not recognize it as a fire-safe building material. Counterintuitively, Bituminous coal, lignite, charcoal, and coke are considered fire-safe, since they only catch fire when they're hot enough (see below).
For the purpose of job item requirements (e.g. in custom reactions or when constructing certain buildings), only bars, blocks, stone, logs, and anvils can be classified as "fire-safe materials" - all other item types are rejected outright. Fire-safe materials are only required when the object is going to come into contact with extreme heat, such as all conventional furnaces and the forge. For the magma-powered versions of these buildings, as well as anything that will be in direct contact with magma (such as floodgates), fire-safe is not enough: it has to be magma-safe.
As far as the game is concerned, only materials which are stable at the temperature 11000 °U (i.e. MELTING_POINT/BOILING_POINT/IGNITE_POINT/HEATDAM_POINT greater than 11000 and COLDDAM_POINT less than 11000) are considered fire-safe. Despite this temperature being considered fire-safe, actual fire can generate temperatures significantly higher - in particular, all burning items generate temperatures up to 200 degrees above their material's ignite point, so once a "fire-safe" item manages to get ignited (e.g. by exposure to magma), it can easily spread further. For practical purposes, anything which has an IGNITE_POINT should be treated as not fire-safe.